Since most conventional boilers are designed to produce super hot water 185 degrees radiant floor company builds what we call split manifolds for multiple zone closed systems that use radiant floor heat in combination with standard baseboard radiators fan coils cast iron radiators or any other hydronic heating device that requires super hot temperatures.
Closed loop radiant floor heating systems.
Types of hydronic floor heating systems image credit.
The decision is strictly up to the consumer for which they prefer.
I used zip ties to tie down the pex pipe.
Pex tubing is flexible easy to install and provides all the characteristics one would need to create a successful open loop or closed loop.
Several decades ago pex replaced polybutylene pb in open loop and closed loop radiant heating installations and the landscape of geothermal heating systems changed forever.
Closed systems are familiar to code officials and contractors and they encounter little resistance.
If they decide that one system should be set up to run the homes radiant floor heating and potable services than an open loop system is required.
The above procedure can be followed to eliminate all air from the system.
Radiantec recommends using a quality domestic water heater instead of a boiler in underfloor radiant heating systems.
More advanced systems include industrial process equipment medical applications dehumidification coils and units and other hydronic heating applications.
If you want to create an argument amongst radiant floor heat installers bring up the subject of open radiant heat systems.
Alternately a utility transfer pump not a sump pump can be used to pump fluid into the system and evacuate the air we recommend a powerful utility pump like the wayne ec 50 or the wayne pc 4 or an equivalent pump like the utilitech 5 hp cast iron transfer pump all of which can generate up to 45 psi.
There are essentially two different methods using a hydronic radiant floor heating system an open loop or a closed loop process.
As per the diagram plan all the pipes end in the utility core to be attached to the radiant floor system inside.
Each length of pex begins in the utility core makes its circuit around its designated zone and comes back so that it will circulate the water in a closed loop heat system.
In an open loop process the water is pulled from a source such as well heated and pumped once through the system before being discarded.
An open radiant floor heat system is one in which the potable water that serves the drinking and bathing needs of the house is also used to heat the floors.
Manifolds and control systems connected to in floor radiant heating.
The system requires an expansion tank.
Air vents remove any trapped air in the.
This i have personally seen being done around my neck of the woods.
These are only a few basic systems.